Contact

Assurance

Owner’s engineer services, client-side inspection, QA/QC and hazardous area compliance. Installed work is checked against the specification and the record, and every finding is followed through to close-out.

Owner’s engineer

Independent technical representation for asset owners and operators: compliance with the specification and Works Information, site surveillance, hold-point witnessing and acceptance.

  • NEC Supervisor services, across all disciplines
  • Contract supervisor services, across all disciplines
  • Inspection against the project specification and all relevant standards and regulations
  • Contract governance and QA/QC
  • Compliance with the specification and Works Information
  • Site surveillance and hold-point witnessing
  • Review of contractor ITPs, ITRs and quality dossiers
  • Findings followed through to close-out and acceptance
  • The record kept in Navus or your document system

Coming soonISO internal and external auditing · Expert witness services

What we do

Owner’s engineer and client representative

Independent technical representation for asset owners: compliance with the specification and Works Information, site surveillance, hold-point witnessing and acceptance.

NEC Supervisor and contract supervisor services for the whole of the works, not one discipline. Inspection against the project specification and all relevant standards and regulations, contract governance and QA/QC.

QA/QC and document control

Quality plans, ITPs, non-conformance reports and corrective actions. Document control, master document registers, transmittals and revision control, in Navus or your document system.

ISO 9001

ITPs and ITRs

Inspection and test plans built from the specification and the contract, with hold and witness points agreed with the client. ITR libraries by discipline, mapped to systems and tags, and tracked through to the quality dossier.

Hazardous areas and DSEAR

DSEAR risk assessments, area classification, Ex registers, and initial, periodic and sample inspections, delivered with our network of Ex specialists. Inspection campaigns can run digitally in Navus.

DSEAR 2002 · BS EN IEC 60079-10-1 · BS EN IEC 60079-17

Asset integrity and inspection

Electrical and C&I inspection regimes, condition assessment of ageing plant, and compliance checks against the original design and current regulations.

Audits

Independent audits of quality systems, construction, completions and hazardous area compliance.

ISO internal and external auditing: coming soon.

ISO 19011

Drone surveys

CAA-licensed drone surveys and aerial thermography of structures and assets that are hard or unsafe to reach.

ATEX and DSEAR inspection

Visual, close and detailed inspections of Ex equipment to BS EN IEC 60079-17: initial, periodic and sample, carried out by CompEx-certified personnel, with our network of Ex specialists for larger campaigns.

  • Ex registers built and kept in Navus
  • Findings recorded against each asset, with photos
  • Remedial work tracked through to close-out
  • DSEAR risk assessments and area classification

DSEAR 2002 · BS EN IEC 60079-17 · BS EN IEC 60079-14 · BS EN IEC 60079-10-1

Drone surveys

CAA-licensed drone surveys and aerial thermography for structures and assets that are hard or unsafe to reach, such as solar arrays, battery storage compounds, roofs and pipe racks. Findings are recorded against the asset, with photos and locations.

From an HLF drone survey of a cable installation.

ITP and ITR lifecycle

How inspection and test plans and reports are managed, from the first draft to the handover dossier.

  1. BuildITPs drafted from the specification, the contract and the construction sequence, with acceptance criteria for every activity.
  2. AgreeHold, witness and review points set with the client, the EPC contractor and any third-party inspectors.
  3. ApproveSubmission, comment and approval cycles run through document control, matched to the contract.
  4. Set up ITRsITR libraries built for each discipline and mapped to systems, subsystems and tags.
  5. ExecuteITRs completed and signed in the field. Hold points are released when the evidence is in.
  6. ReviseTemplates updated when scope or specifications change. Superseded versions are withdrawn.
  7. Close outCompleted ITPs and ITRs compiled into the quality dossier and handover packs.

Contact

Tell us about the scope, the contract and the programme. We reply to enquiries within one working day.